Underfloor insulation in NZ: what to know before you lay new floors
Underfloor insulation in NZ before new floors go down: moisture and vents, R-values, the rental R1.3 rule, old foil, costs and Warmer Kiwi Homes grants.

Key numbers
Underfloor insulation in NZ, as at November 2026
- Rental minimum
- R1.3
- EECA and Gen Less advice
- At least R1.4
- Installed, R1.3–R1.6 (installer rate)
- About $12–$25/m²
- 100 m² job (two published guides)
- About $1,500–$3,000
- Ground moisture barrier
- About $7–$15/m² installed
- Warmer Kiwi Homes
- 50%, 80% or 90% for eligible owner-occupiers; not rentals
- Old foil
- Installing or repairing it in homes with existing wiring banned since 1 July 2016
Checked November 2026.
Should you insulate under the floor before new flooring goes down? Yes, if you can get under it. Fix any damp first, because once the floor is laid the subfloor is out of sight. Rentals must have at least R1.3 insulation under every suspended floor below a living space, with narrow exceptions. A suspended floor has a gap underneath and is usually timber; a concrete slab laid on the ground can’t be insulated from below. Installing or repairing foil insulation is banned in homes with existing wiring. You don’t need building consent to insulate under an existing home.
The short version
- Rentals: at least R1.3 under suspended floors (an R-value measures how well insulation resists heat flow; higher is better). Owner-occupiers aren’t legally required to insulate, but EECA and Gen Less suggest at least R1.4 if you do.
- Ground moisture barrier: a separate rule. Since 1 July 2025, every rental with an enclosed subfloor (airflow significantly blocked along at least half its perimeter) has needed one, if it’s possible to install one.
- Old foil: installing or repairing it in a home with existing wiring has been banned since 1 July 2016. Don’t patch it, and don’t touch foil held with metal staples.
- Consent: not needed to insulate or lay a ground moisture barrier under an existing home.
- Cost: about $12–$25/m² installed for R1.3 to R1.6 products, going by one Auckland installer’s rates, and about $1,500–$3,000 for a typical 100 m² job in two published guides (others are higher).
- Grants: Warmer Kiwi Homes covers 50%, 80% or 90% of the cost for eligible owner-occupiers, not rentals. Installation can take up to four months.
Landlord? Jump to what the healthy homes standards require and the ground moisture barrier rule.
Should you insulate under the floor before replacing your flooring?
BRANZ says there’s no legal requirement to retrofit insulation in an older owner-occupied house, but EECA calls insulating the space between the floor and the ground “one of the easiest and most cost-effective ways” to make a home more comfortable. On timing, EECA says: “If you can’t access the subfloor area, a good time to add insulation is when you’re making changes to the floor like repiling or replacing floorboards.”
Repairs come first. BRANZ lists borer, rot, corroded fixings, wiring problems (call a registered electrical worker), leaks and dampness, and says “All repair work should be completed before the insulation is installed.”
Lifting old vinyl? WorkSafe says a house built before 1 January 2000 probably contains some asbestos, and lists vinyl flooring (backing and adhesive included) among the places it’s found. Get it checked before anyone cuts or lifts it; see our guide to checking vinyl flooring for asbestos.
How the subfloor affects the floor above
Damp under a house shows up in the rooms above. BRANZ’s list of what goes wrong includes mould, sagging joists, swollen particleboard and “bubbling under vinyl or rotting of carpet”. A new floor just covers that up.
Don’t count on the floor covering to insulate, either: two laminate data sheets give R-values of 0.051 and 0.055 m²K/W, so R1.3 insulation has about 24 to 25 times the R-value of either (our arithmetic). That said, carpet and underlay do resist heat flow (H1/AS1, the Building Code’s insulation guidance, notes that carpet reduces the efficiency of a heated floor), which in our view is part of why carpet feels warmer underfoot than hybrid.
Suspended timber floor or concrete slab: which do you have?
A suspended floor is a timber floor held up on piles, with bearers (the main beams) and joists (the smaller beams the floorboards sit on). The gap underneath is the subfloor. A slab is concrete poured straight onto the ground. Vents around the base of the outside walls and a crawl space underneath mean you’ve got a suspended floor. BRANZ has estimated about 1.2 million existing NZ homes have one.
How much space do you need under the floor?
EECA and Gen Less both say that if there’s more than half a metre of space under the floor, insulation can go in fairly easily between the joists. One Auckland installer’s cost guide says crawl spaces lower than 400 mm push up labour costs.
Can you insulate a concrete slab floor?
Not the slab itself. EECA says a concrete slab “itself can’t be insulated”, but you can insulate around its perimeter with vertical strips. BRANZ’s Level site says slab floors are usually insulated with polystyrene board laid over the damp-proof membrane before the concrete is poured, so the real chance comes at build time.
Underfloor heating and heat pumps
For new building work, the Building Code’s acceptable solution H1/AS1 sets a minimum construction R-value of R2.5 to R3.0 for a heated floor, slab or suspended timber, that’s part of the home’s thermal envelope (the insulated shell between heated rooms and outside). The figure depends on the Building Code climate zone (not the healthy homes zones) and counts the whole floor construction, not just the insulation product. The minimum doesn’t apply where the floor heating is only in rooms with a shower, bath or toilet, and our explainer on the H1 changes has the zone-by-zone figures. For floating floors, our laminate vs hybrid guide sets out each maker’s underfloor heating rules.
Insulation doesn’t add heat; it slows the loss of the heat your heat pump makes. BRANZ notes that too much ventilation combined with too little insulation can lead to unwanted heat loss through the floor.
Subfloor moisture and ventilation: check these before you insulate
Insulation and a new floor both do best when the subfloor is dry. BRANZ’s damp test: rub some dirt from under the house on your hand. If it stains like mud, there’s probably too much moisture. If so, BRANZ suggests working in this order:
- Clear anything blocking airflow, and uncover blocked vents.
- Stop water flowing under the house, and check the cladding clearances (the gap between the bottom of the wall cladding and the ground).
- If it’s still damp, add vents or cover the ground with polythene. BRANZ’s House Insulation Guide specifies 0.25 mm (250 micron) sheet overlapped 150 mm at the joints and butted against the foundation walls and piles.
For older houses, our guide to flooring Auckland villas covers how to fix subfloor moisture.
How much subfloor ventilation should you have?
BRANZ applies the timber-framing standard’s figure for new houses to existing ones too: ventilation openings of at least 3,500 mm² per m² of floor area, spread evenly around the foundation perimeter. Its 2013 guide to damp subfloors reported that 66% of houses in its house condition surveys (1994 to 2010) didn’t meet the subfloor ventilation requirements.
Don’t block vents to make the floor feel warmer. That’s what insulation is for. BRANZ recommends checking the subfloor once a year.
What does a ground moisture barrier do?
A ground moisture barrier is a sheet, usually polythene, laid over the soil under the house to cut the moisture coming up from the ground. EECA says that in an enclosed subfloor (one closed in around its edges), a polythene ground sheet “can help reduce moisture levels” and help the insulation work better. Landlords have a separate legal rule (see below).
Underfloor insulation types and what R-value to buy
Under timber floors, Level says the usual choices are polystyrene boards, which must fit hard against the underside of the floor and tight between the joists, or fibre sheets and blankets (glasswool, wool, polyester, a wool and polyester mix, or mineral wool) fitted between the joists and securely fixed or strapped.
What R-value should you buy?
| Situation | R-value |
|---|---|
| Rental (healthy homes standards) | At least R1.3, covering the suspended floor under living spaces |
| Owner-occupier, DIY (EECA and Gen Less advice) | At least R1.4 (“or higher if you can”, in Gen Less’s words) |
| BRANZ advice | The highest-performing insulation you can afford, as long as the joists are deep enough to fit it properly |
What to check on the product and the install
- Made for underfloor use and compliant with AS/NZS 4859.1, the insulation materials standard (BRANZ’s House Insulation Guide cites the 2018 edition).
- Protected if the subfloor is open. EECA says use a product rated for windy conditions; Level says add a sheet lining such as plywood or fibre-cement.
- Hard against the floor, with no gaps, sagging or missing pieces (EECA) and no air gap (BRANZ).
- Clear of cables. BRANZ says to take great care with cables if stapling to joists, and to keep polystyrene away from PVC-sheathed cables, which may react chemically with it over time.
Is foil underfloor insulation banned in NZ?
Safety: Turn the power off before anyone goes near old foil under a house. If you have any doubt about the foil or the wiring, get a licensed electrical worker in first. Our health and safety guide covers asbestos and electrical safety on flooring jobs.
The rule. Installing or repairing it is, in homes with existing wiring. MBIE Ban 2016/001, in force since 1 July 2016 under section 26 of the Building Act 2004, bans installing or repairing foil insulation (for example, stapling ripped foil back onto the joists) in residential buildings with an existing electrical installation. It applies to underfloor areas, ceilings and walls, and to anyone, homeowners included. A breach is an offence under section 27 of the Act, with a fine of up to $200,000 on conviction, and councils mainly enforce it.
Why. MBIE says fasteners can pierce live cables, and because foil conducts electricity, the whole underfloor area can potentially become live. Nor is it just metal staples: “Nylon fasteners also have some risk”.
What’s excluded. New homes or additions with no existing electrical installation, and foil supplied pre-fixed to rigid materials such as plasterboard or polystyrene.
Existing foil isn’t illegal to have, but it’s not much use. MBIE’s Smarter Homes guide says the foil “does not provide sufficient insulation”, and Level says it can get dusty, torn or damaged and lose its effectiveness.
What to do about old foil under the floor
- Don’t touch it if it’s held with metal staples. Gen Less: “There’s a risk of electrocution.”
- Don’t patch rips. Gen Less: “you must not try to repair it – it’s banned.”
- Get it removed properly. EECA says damaged foil must be “very carefully removed with the power off and replaced with a modern bulk underfloor insulation”. BRANZ agrees, and suggests considering a registered electrician.
One installer’s online calculator lists underfloor foil removal as an optional extra at $1.50–$2/m².
In a rental, damaged foil fails, and foil in reasonable condition passes only under the partial exemption. Tenancy Services says that if existing underfloor foil “is ripped, not shiny or there are gaps, it will not meet the requirements of the insulation standard”, and it must be replaced with new non-foil insulation that meets the minimum R-value. Foil in reasonable condition passes only if it meets the partial exemption below: installed when the home was built or converted, and backed by compliance documents.
Healthy homes standards: what a rental needs under the floor
In Tenancy Services’ words, “Ceiling and underfloor insulation is compulsory in all rental homes.” It has been since 1 July 2019, and all private rentals have had to comply with the healthy homes standards since 1 July 2025.
| Requirement | What it means |
|---|---|
| R-value | At least R1.3 under the floor, in all three climate zones |
| Coverage | A suspended floor under a living space must be fully covered (regulation 15) |
| Installation | New insulation installed to NZS 4246:2016 (the NZ installation standard) |
| Condition | “Reasonable condition”: “no mould, dampness, damage or gaps” |
| Penalty | Breaching landlord obligations can bring financial penalties of up to $7,200 |
Full cover has two exceptions under regulation 15: another living space directly below, and clearances reasonably needed around things in or under the floor. Layers of insulation count together (their R-values are added).
Exemptions
Tenancy Services lists three:
- Access is impracticable or unsafe. Having to create an access way doesn’t make it impracticable. Tenancy Services’ examples are a concrete slab, where there’s “no suspended floor area in which to install insulation”, and parts of a floor out of reach because of the slope of the land or a lack of space.
- Partial exemption for existing insulation installed when the home was built or converted, still in reasonable condition, with compliance documents such as a code compliance certificate.
- Floors with another habitable space directly below.
Under regulation 19, a floor that can’t reasonably be insulated at the start of a tenancy is exempt, but the exemption ends if insulating becomes reasonably practicable during the tenancy. In our view, a re-floor that opens up the subfloor may well be that moment.
For records, Tenancy Services suggests installation records, an installer’s certificate, a product label, an invoice or council records, and it has an online insulation tool for rental properties.
Does a rental need a ground moisture barrier?
Yes, if it has an enclosed subfloor: Tenancy Services says a barrier “must be installed if it is possible to do so”. Under the regulations, a subfloor counts as enclosed if airflow is significantly blocked along at least half its perimeter.
The barrier rule sits in the moisture ingress and drainage standard, not the insulation standard, so a rental can meet one and fail the other.
Regulation 28 accepts two options:
- Polythene, in practice. Material meeting the on-ground vapour barrier specification in section 8 of NZS 4246:2016, installed to that section. Tenancy Services says this is generally a polythene sheet, which the owner or a building professional can lay.
- Another material, laid by a professional. A barrier with a vapour flow resistance of at least 50 MN s/g, installed by a professional installer. Vapour flow resistance, measured in MN s/g (meganewton seconds per gram), is how well a material stops moisture vapour; higher is better.
The exemption. A landlord doesn’t have to install a barrier if a professional installer can’t get to the area without substantial building work, substantial damage or greater than normal health and safety risk, or if it’s otherwise not reasonably practicable. Where polythene can’t go in, no alternative is needed. Tenancy Services’ example is limited space, confirmed by a professional installer.
How much does underfloor insulation cost in NZ?
Underfoot hasn’t collected quotes. The table uses three published NZ guides from businesses that sell the work: two Auckland installers and an undated article from a national renovation firm.
| Item | Published range | Source |
|---|---|---|
| Polyester, R1.3–R1.6 | $12–$25/m² | Auckland installer’s guide (updated 1 Nov 2026) |
| Polyester, R1.8–R2.6 | $15.50–$24/m² | Auckland installer’s calculator (prices checked 15 Oct 2026) |
| 100 m² floor, R1.3–R1.6 | $1,500–$3,000 | Auckland installer’s guide; a renovation firm’s cost article |
| Ground moisture barrier | $7–$15/m² ($7.50–$10/m² on the calculator) | Both installer sources |
Two online cost calculators put underfloor insulation at about $15–$30/m² and $15–$35/m² installed, and two other 2026 guides put ceiling and underfloor insulation at about $35–$60/m², so treat the low end with caution. One of those higher guides is from Superior Renovations, whose group also includes the Auckland installer behind the $12–$25/m² rate.
Our reading: roughly $1,500–$3,000 per 100 m² of floor for R1.3 to R1.6 products going by the installers’ published rates, plus about $700–$1,500 if the subfloor needs a ground moisture barrier. Firms charging the rates in the higher-priced guides will cost more.
The Auckland guide says price depends on R-value and access as much as the material, so make sure each quote names the product, the R-value, the area and whether a moisture barrier is included. For the floor itself, see our NZ flooring cost guide for every floor type. We plan to re-check these prices in February or March 2027.
Can you install underfloor insulation yourself?
You can. Gen Less says everything you need to know is in NZS 4246, and recommends reading the health and safety advice in its Appendix B carefully. If you’re paying someone, Gen Less suggests quotes from at least two trained installers. If there’s old foil, read the foil section first.
Warmer Kiwi Homes: can you get an underfloor insulation grant?
If you own and live in the house, possibly. If it’s a rental, no. As at November 2026, EECA’s Warmer Kiwi Homes page lists insulation grants of 90% for Community Services Card or SuperGold Combo card holders or people in a high-need area, 80% in certain areas, and 50% in a middle-income area.
To qualify, you need to own and live in a home built before 2008, and either have a Community Services Card or SuperGold Combo card or live in an area identified as low to middle income. The home also can’t already have both ceiling and underfloor insulation. EECA’s eligibility checker takes about five minutes, or you can phone 0800 749 782.
Not covered: rentals and homes owned by businesses, baches, Airbnbs and holiday homes, and wall insulation.
Worth knowing: funding is limited and installation can take up to four months. If the home is assessed as needing insulation, funding can also cover access work (creating access to underfloor areas you can’t get into, and fixing minor leaks under the floor). The Government told a parliamentary select committee in 2025 that the programme supports a moisture barrier where an insulation job needs one.
EECA puts an average ceiling and underfloor retrofit at about $4,300, so about $2,150 after the 50% grant. At 80% or 90%, expect to pay $280 to $800, depending on the size of the house and whether ceiling, underfloor or both are needed. The programme runs under a time-limited government grant scheme (2023–2028), so check before you plan around it.
Do you need a building consent for underfloor insulation?
Not in an existing home. Schedule 1 of the Building Act 2004 exempts installing insulation in an existing building (clause 13), except in an external or fire separation wall, and separately exempts a ground moisture barrier in an existing subfloor (clause 13A). The work still has to meet the Building Code. Replacing the floor finish doesn’t need consent either: our explainer on the Building Amendment Bill covers that exemption.
New homes and consented work must meet Building Code clause H1, and from 27 November 2026 only its updated acceptable solutions and verification methods can be used for new building consent applications.
Before you order new flooring: a checklist and next steps
Before you sign a flooring quote, check:
- Subfloor: access and clearance known, soil dry, vents clear, a ground moisture barrier down where needed.
- Repairs and foil: rot, borer, wiring and leaks fixed; any foil left alone until an electrician has looked.
- Insulation: R-value, product and NZS 4246:2016 install recorded, with the certificate or invoice filed (essential for a rental).
Then:
- Sort the subfloor first, with itemised insulation and moisture quotes, and check Warmer Kiwi Homes eligibility if you own and live in the house.
- Then plan the floor. Our guide to what happens on flooring installation day covers subfloor prep.
- Vet whoever does the work. For insulation, Gen Less recommends an Insulation Association of NZ member. For the floor, our guide on how to vet a flooring installer is written for Auckland, but most of its checklist works anywhere in NZ.
Methodology and sources
Checked 24 Nov 202635 sources
Cost ranges compiled from published NZ installer and cost-guide pricing, checked on 24 November 2026. Sources are listed below. Underfoot has not collected quotes or tested any product. Rules are quoted from Tenancy Services, the Residential Tenancies (Healthy Homes Standards) Regulations 2019, MBIE, EECA and the Building Code’s acceptable solution H1/AS1. Maker and installer statements are attributed as theirs. Warmer Kiwi Homes details are from EECA’s programme page as at November 2026 and can change.
Healthy homes standards (rentals) (6)
Foil insulation (4)
Insulation, moisture and ventilation guidance (9)
- EECA: insulate your home
- Gen Less: underfloor insulation
- BRANZ: subfloor ventilation
- BRANZ: retrofitting underfloor insulation
- BRANZ: House Insulation Guide, sixth edition (PDF)
- BRANZ: damp subfloors guide (BK105, 2013), via Building Performance codehub
- BRANZ Level: options for floor insulation
- Building Performance: H1/AS1 Energy efficiency, sixth edition (PDF)
- WorkSafe: where asbestos can be found
Floor coverings (2)
Prices (installer guides, attributed) (3)
Other published cost guides (4)
- Calk.nz: insulation calculator (published 28 March 2026, last reviewed 17 November 2026)
- TradieTools NZ: insulation installation cost NZ 2026 (updated 23 June 2026, GST inclusive)
- Superior Renovations: insulating a house in NZ (updated 1 November 2026)
- CheckMyBuilder: insulation installation cost (June 2026, excludes GST)
Grants and consent (7)
- EECA: Warmer Kiwi Homes programme information
- EECA: Warmer Kiwi Homes eligibility
- Answers to select committee questions on Vote Energy, 2025/26 Estimates (Q114)
- EECA: Statement of Performance Expectations 2026/27 (PDF)
- Building Performance: exempt work, ground moisture barrier
- Building Act 2004
- Building Performance codehub: H1/AS1 sixth edition
Choosing what goes on top once the subfloor is sorted? Read our guide to choosing between carpet, vinyl plank and hybrid in NZ.